OLCT 80/OLCT 80 Wireless

  • A triple head multi-function transmitter
  • On-board display
  • 3 built-in relays for fault, low and high alarms (alarms in relay are fully programmable)
  • Two 4-20 mA inputs, built in relays, memory settings and requests by remote control
  • 4-20 mA and RS 485 outputs, loop connection
  • New Wireless Version available suitable for explosive areas
  • Flameproof or intrinsic-safety sensors
  • Low power requirements;
  • Universally accepted frequency of 2.4 GHz/900MHz; and
  • Flexible input/output options, including analog, TOR and Modbus RS485

Product Information

Overview

NEW! Oldham is pleased to introduce its wireless system with the OLCT 80 field detector/transmitter. This new model allows wireless connectivity in ATEX 1 zones.

Features and benefits of the OLCT 80 Wireless include:

  • An infrared remote controller and on-board display for non-intrusive, one-man calibration;
  • Flameproof or intrinsic-safety sensors;
  • A design suitable for explosive areas;
  • Low power requirements;
  • Universally accepted frequency of 2.4 GHz/900MHz; and
  • Flexible input/output options, including analog, TOR and Modbus RS485

Developed in compliance with the strictest specifications, OLCT 80 transmitters are the standard in the gas detection market.

Designed to meet the demanding needs of the largest industrial companies, the OLCT 80 is a major achievement in terms of technical performance and cost optimization.  Available as remote version, flameproof or intrinsic safety approved sensors depending on gases to be detected. Detects O2, combustible, toxic and refrigerant gases. Non-intrusive, one-man calibration.

New XP IR infrared sensor for detection of combustible gases or CO2

Specification

Technical Specifications

Type:

Transmitter-sensor

Detected gases:

Explosive, toxic and oxygen

Detection principles:

Catalytic, Electrochemical, IR, Semiconductor

Sensor block:

Pre-calibrated

Housing Sensor:

Stainless steel 316L

Enclosure:

Aluminum

Visualization:

4-digit LCD display for measurement and one alphanumeric line for texts
Pictograms - backlighting
4 indicator lamps :

  • one green : "Operation OK"
  • one yellow : "Fault"
  • 2 red : "Alarm 1" and "Alarm 2"

Power supply to sensor terminals:

Two independent inputs:
16 to 28 VDC ( catalytic / IR / SM cells)
12 to 28 VDC (electrochemical cell)

Maximum power

with digital link:

0.2 W (electrochemical cell) -1.3W(catalytic/SM) -4.5W(IR)

with I output at 25 mA :

0.9 W (electrochemical cell) -2W(catalytic/SM) -5.2W(IR)

with I output at 25 mA and relays activated:

2.4 W (electrochemical cell) -3.5W(catalytic/SM) -6.7W(IR)

Inputs:

Two analog inputs 4-20 mA (load resistance 120 Ω, can be used as binary)

Signal Outputs

Logic (relay contacts):

Relay

Analog:

Standardized 4-20 mA output

Digital:

Two independent opto-isolated RS 485 ports

Signal faults:

I < 0.5 mA

Alarms:

2 programmable thresholds per channel

Relays

Type:

SPDT

Number:

3

Contact:

RCT changer-over

Breaking capacity:

2A / 250 VAC / 30 VDC

Miscellaneous

Wiring / connection:

Basic version, 6 inputs : 4 M20 and 2 M25
On request: 3 additional,2 M20 and 1 M25

Load resistance on the 4-20 mA:

500 Ω

Loop resistance:

Under central unit 21 VDC: 128 ohms ( electrochemical cell ) - 32Ω(catalytic/SM)-16Ω(IR)

Protection number:

IP 66

Operating temperatures:

-25°C to +55°C

Weight:

OLCT 80 : 3,5 kg
OLCT80 version IR : 5,3 kg

Certification Atex :

OLCT 80 d
II 2GD
EEx d IIC T5( T100°C) or T6 (T85°C)
INERIS 03ATEX0240X

OLCT 80 id (with intrinsic safety sensor block)
II 2GD
EEx d [ia] ia IIC T4 (T135 °C)
INERIS 03ATEX0240X

Electromagnetic compatibility:

Complies with EN 50270

Sensor Technical Specifications

Gases Type of sensor Range (ppm) Operating temperature* Relative humidity uncondensed Pressure Accuracy at full scale (at atmospheric pressure) Life span (in month) T (50) IP IS AD
O2 electrochemical 30,00% -20°C to +50°C 10% to 95% RH Atm +/- 10% from 5 to 30% = 0,4%vol 28 6 66 YES YES
CO electrochemical 100, 300 and 1000 -20°C to +50°C 10% to 95% RH Atm +/- 10% +/- 2 ppm (range 0-100) 48 10 66 YES YES
H2S electrochemical 30, 100 and 1000 -20°C to +50°C 10% to 95% RH Atm +/- 10% +/- 1,5 ppm (between 0-30 ppm) 48 15 66 YES YES
NO electrochemical 100, 300 and 1000 -20°C to +50°C 10% to 95% RH Atm +/- 10% +/- 2 ppm (range 0-100) 36 15 66 YES YES
NO2 electrochemical 10 and 30,0 -20°C to +50°C 10% to 95% RH Atm +/- 10% +/- 0,8 ppm 26 20 66 YES NO
SO2 electrochemical 10,0 30,0 and 100 -10°C to +50°C 10% to 95% RH Atm +/- 10% +/- 0,7 ppm range 0-10 36 15 66 YES NO
Cl2 electrochemical 10,0 -20°C to +50°C 10% to 95% RH Atm +/- 10% +/- 0,5 ppm 26 50 66 YES NO
H2 electrochemical 2000 -20°C to +50°C 10% to 95% RH Atm +/- 10% +/-5 ppm range 0-100 26 50 66 YES YES
HCl electrochemical 30,0 and 100 -20°C to +40°C 10% to 95% RH Atm +/- 10% +/- 0,5 ppm range 0-10 26 50 66 YES NO
HCN electrochemical 10,0 and 30,0 -20°C to +40°C 10% to 95% RH Atm +/- 10% +/- 0,3 ppm range 0-10 26 40 66 YES NO
NH3 electrochemical 100 -20°C to +40°C 10% to 95% RH Atm +/- 10%
Atm +/- 10%
+/-5 ppm
+/- 10 ppm range 0-1000
26
26
50
50
66
66
YES
YES
YES
YES
    1000 -20°C to +40°C 10% to 95% RH Atm +/- 10% +/-0,05 ppm 20 50 66 YES NO
O3 electrochemical 1,00 -10°C to +40°C 10% to 95% RH Atm +/- 10% +/- 0,05 ppm 20 40 66 YES NO
PH3 electrochemical 1,00 -20°C to +40°C 10% to 95% RH Atm +/- 10% +/- 0,3 ppm 26 50 66 YES NO
ClO2 electrochemical 3,00 -20°C to +50°C 10% to 95% RH Atm +/- 10% +/- 1 ppm 20 40 66 YES NO
SiH4 electrochemical 50 -20°C to +40°C 10% to 95% RH Atm +/- 10% +/- 0,05 ppm 26 40 66 YES NO
AsH3 electrochemical 1,00 -10°C to +40°C 20% to 95% RH Atm +/- 10% 1% vol 60 5 66    
CH4 catharometre 0-100%vol -20°C to +50°C 10% to 95% RH Atm +/- 10% 1% vol 60 5 66 YES YES
H2 catharometre 0-100%vol -20°C to +50°C 10% to 95% RH Atm +/- 10% 100 ppm 36 8 66 YES YES
NH3 catalytic 0-5000 -20°C to +50°C 10% to 95% RH Atm +/- 10% 1% lIE between 0- 60%LIE 60 5 66    
Flammable gas catalytic 0-100% LIE -20°C to +70°C
-20°C to 200°C
10% to 95% RH
10% to 95% RH
Atm +/- 10% 1% lIE between 0- 60%LIE 60 5 66    
VOC semi-conductor 500 ppm -20°C to +50°C 10% to 95% RH Atm +/- 10% 100 ppm +/-5 ppm 30 25 66 NO YES
CO/H2 null electrochemical 1000 ppm -20°C to +50°C 10% to 95% RH Atm +/- 10% +/- 4 ppm if measure < 200 ppm 36 25 66 YES YES
CO sensor           +/-20 ppm if measure>200 ppm       YES YES

 

Documentation
OLCT 80 Literature Sheet (English)
OLCT 80 Manual (English)
OLCT 80 Wireless Technical Data Sheet (English)
Certifications
OLCT 80 Wireless ATEX Approval
OLCT 80 Wireless Remote Control ATEX approval
OLCT 80 ATEX Approval
ATEX ZONE 0 (sensor only) or 1
Gases: 
AsH3
ClO2
CO
CO2
H2
H2S
HCl
O3
HF
C2H4O
CO/H2 null
COCl2
HCN
NH3
NO
NO2
O2
PH3
SiH4
SO2
VOC
  • Printer-friendly versionPrinter-friendly version

Product Types

  • Fixed Controllers
  • Fixed Transmitters
  • Fixed Accessories
  • Legacy Products
  • Product Policies

Share Your Success

See our full line of fixed gas detection products.

Share Your Success

Help us save more lives. Share your success with using Oldham fixed gas detection products and services.

You are here

Home

We’re here to help

Americas: +(1) 1-800-DETECTS
EMEA: +(33) 3 21 60 80 80
Asia-Pacific: +(86) 21 5899 3279

Feedback

Please take our Customer Satisfaction Survey.

The Industrial Scientific Family of Companies

Industrial Scientific: Portable Gas DetectorsOldham Gas: Fixed Gas DetectorsPredictive Solutions: Safety Software

Terms of Use | Privacy Statement

Copyright 2013 Oldham Gas. All Rights Reserved. Web site by Impactiv, Inc.