Detectors |
OLCT 50 |
OLCT 50D |
OLC 50 |
OLC 50D |
|---|
|
Type |
Flameproof transmitter |
IS transmitter |
Flameproof transmitter |
IS remote transmitter |
Flameproof detector |
Remote Flameproof detector |
|
Gas detection principle |
Catalytic/ Electrochemical |
Electrochemical |
Catalytic/ Electrochemical |
Electrochemical |
Catalytic |
Catalytic |
|
Detected gases |
Flammable and toxic gasses, oxygen |
Toxics and oxygen |
Flammable, toxics and oxygen |
Toxics and oxygen |
Flammable gasses |
Flammable gasses |
|
Measuring range |
See chart inside |
|
Enclosure |
Alloy AS7 606 - epoxy polyester paint |
|
Sensor housing |
Stainless steel type 316 L |
|
Precalibrated sensor |
yes |
>yes |
yes |
yes |
no |
no |
|
Power supply at the detector |
15 to 30 VDC (catalytic) 10 to 30 VDC (chemical) |
>10 to 26 VDC |
15 to 30 VDC (catalytic) |
10 to 26 VDC
10 to 30 VDC (chemical) |
2,7 VDC max |
2,7 VDC max |
|
Maximum power consumption |
100 mA (catalytic)
25 mA (chemical) |
>25 mA |
100 mA (catalytic) |
25 mA 25 mA (chemical) |
350 mA max |
350 mA max |
|
Output signal |
4-20 mA |
4-20 mA |
4-20 mA |
Wheatstone bridge |
Wheatstone bridge |
|
Load impedance |
250 Ω (catalytic) Depending on power supply (chemical) |
47 Ω max |
250 Ω (catalytic) |
47 Ω max Depending on power supply (chemical) |
Not applicable |
Not applicable |
|
Wiring |
3 reinforced wires (catalytic)
2 reinforced wires (chemical) |
2 reinforced wires |
3 reinforced wires |
2 reinforced wires (catalytic)
2 reinforced wires (chemical) |
3 reinforced wires |
3 reinforced wires |
|
Loop impedance |
32 Ω (catalytic) (1 km with 1,5 mm2)
128 Ω (chemical) (4 km with 1,5 mm2) |
32 Ω (1 km with 1,5 mm2) |
32 Ω (1 km with 1,5 mm2) 128 Ω (chemical) (4 km with 1,5 mm2) |
32 Ω (1 km with 1,5 mm2) |
32 Ω (1 km with 1,5 mm2) |
32 Ω (1 km with 1,5 mm2) |
|
Wiring connection |
Gland - cable 2 to 12 mm (standard) |
|
Fastening |
2 x 7 mm holes |
|
Ingress protection |
IP 66 |
|
Certification |
EEx d IIC T6
II 2 GD
INERIS 01 ATEX 0027X |
EEx ia IIC T4
II 1 GD
INERIS 01 ATEX 0027X |
EEx ia IIC T6
ATEX II GD
INERIS 01 ATEX 0027X |
EEx ia IIC T4
ATEX II GD
INERIS 01 ATEX 0027X |
EEx d IIC T6
ATEX II 2 GD
INERIS 01 ATEX 0027X |
EEx d IIC T6
ATEX II 2 GD
INERIS 01 ATEX 0027X |
|
CEM mark |
EN 50270 |
EN 50270 |
EN 50270 |
EN 50270 |
EN 50270 |
EN 50270 |
|
Weight |
1,9 kg |
1,1 kg (casing) |
1,1 kg |
1,1 kg |
|
Dimensions |
L 154 x l 233 x H 121 |
L 154 x l 233 x H 121 |
L 154 x l 170 x H 121 |
L 154 x l 170 x H 121 |
L 154 x l 160 x H 121 |
L 154 x l 160 x H 121 |
|
Operating temperature |
-25°C to +60°C |
-25°C to +60°C |
-25°C to +70°C
-25 °C to +200°C
in HT version in HT version |